XAM 8000
Request a QuoteDräger X-am 8000 — Multi-Gas Detector
Clearance measurement was never this easy and convenient: The 1-to-7 gas detector detects toxic and flammable gases as well as vapors and oxygen all at once - either in pump or diffusion mode. Innovative signaling design and handy assistant functions ensure complete safety throughout the process.
Technical data / ordering — catalogue p. 133
Technical data
Dimensions (H x W x D) 7 x 3 x 1.7 in (179 x 77 x 42 mm)
Approx. 17.5 oz (495 g), depending on sensor configuration, without strap, without pump
Weight
Approx. 19 oz (550 g), depending on sensor configuration, without strap, with pump
Housing Durable two-component housing
Display High-contrast color display
Temperature -4 to 122 F (-20 to 50 C)
700 to 1,300 hPa (measuring function)
Pressure
800 to 1,100 hPa (use in explosion-hazard areas)
Relative humidity 10 to 90 % (short-term up to 95 %) r.h.
3 LED 'red' (gas alarms),
Visual:
3 LED 'yellow' (device alarms)
Alarms
Acoustic Multi-tone, typically 100 dB at 12 in (30 cm)
Vibration
Ingress protection class IP 68
Energy supply Lithium-ion battery, rechargeable, inductive charging
With CatEx and 3 EC sensors Typically 24 hours
With IR and 3 EC sensors Typically 22 hours
With 3 EC sensors Typically 120 hours
Operating times (Diffusion) With CatEx, PID and 3 EC sensors Typically 17 hours
With IR, PID and 3 EC sensors Typically 16 hours
With CatEx-, IR- and 3 EC sensors Typically 14 hours
PID only Typically 42 hours
Charging times Typically 4 hours after use during a shift of max. 10 hours
Start-up times Typically <60 seconds for standard sensors
24 MB, e.g. at 10 minutes per hour of gas exposure with measuring values changing by the
Data storage
second on all 7 channels: approx. 400 hours
Pump operation Max. hose length 148 ft (45 m)
Marking Explosion Protection:
I M1, II 1G
ATEX />IECEx
Ex da ia I Ma, Ex da ia IIC T4 Ga
Approvals
Class I, Zone 0, AEx da ia IIC T4 Ga
cCSAus Class II, Div. 1, Gr. E, F, G
C22.2 No. 152, ANSI-ISA 12.13.01:2000
3 years for the device
Manufacturer´s warranty 2 years for the power supply
Sensors: see DrägerSensor & Portable Instruments HandbookSource: Dräger Safety Product Catalog 2026 — Industrial Applications (US edition, ebk 9108764), pp. 127–133. Matched by exact model name. US-edition approvals (NIOSH / CSA / NFPA) and order numbers may differ for the Indian variant — confirm with Dräger Safety India before quoting.